• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental Investigation of the Influence of Moisture on the Bond Behavior of FRP to Concrete Interfaces

    Thumbnail
    View/Open
    %28asce%29cc%2E1943-5614%2E0000145.pdf (903.5Kb)
    Date
    2010
    Author
    Jian-Guo Dai
    Hiroshi Yokota
    Mitsuyasu Iwanami
    Ema Kato
    Metadata
    Show full item record
    Abstract
    The effects of moisture on the initial and long-term bonding behavior of fiber reinforced polymer (FRP) sheets to concrete interfaces have been investigated by means of a two-year experimental exposure program. The research is focused on the effects of (1) moisture at the time of FRP installation, in this paper termed “construction moisture,” consisting of concrete substratum surface moisture and external air moisture; and (2) moisture, in this paper termed “service moisture,” which normally varies throughout the service life of concrete. Concrete beams with FRP bonded to their soffits were prepared. Before bonding, concrete substrates were preconditioned with different moisture contents and treated with different primers. The FRP bonded concrete beams were then cured under different humidity conditions before being subjected to combined wet/dry (WD) and thermal cycling regimes to accelerate the exposure effects. Adhesives with different elastic moduli were used to investigate the long-term durability of each adhesive when subjected to accelerated WD cycling. Pull-off tests and bending tests were conducted at the beginning of the cycling and then again after 8 months, 14 months, and 2 years of exposure so as to evaluate the tensile and shear performance of the FRP-to-concrete interfaces. It was found that the effect of the concrete substrate moisture content on short-term interfacial bond performance could be eliminated if an appropriate primer was used. All FRP-to-concrete bonded joints failed at the interface between the primer and concrete after exposure while those not exposed usually failed within the concrete substrate. After exposure to an environment of accelerated WD cycles, it was also found that the interfacial tensile bond strength degraded asymptotically with the exposure time while the flexural capacity of the FRP sheet bonded plain concrete beams even increased. The mechanism behind the above, which is an apparently contradictory phenomenon, is discussed.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/57261
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV