Show simple item record

dc.contributor.authorValter Carvelli
dc.contributor.authorGiulia Fava
dc.contributor.authorMarco A. Pisani
dc.date.accessioned2017-05-08T21:36:03Z
dc.date.available2017-05-08T21:36:03Z
dc.date.copyrightOctober 2009
dc.date.issued2009
dc.identifier.other%28asce%29cc%2E1943-5614%2E0000030.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/57139
dc.description.abstractThe scope of this paper is to describe the development of an anchor system for tension testing of unidirectional fiber-reinforced plastic bars of large diameter used as reinforcement in concrete structures. The main objective was to develop a simple, economical, and effective system to permit tensile loading of the bars up to failure in a universal testing machine. In the system suggested, each end of the bar is embedded in a conical polymeric head that fits a conical hole inside the anchoring device. In the experimental tests performed, the bars broke between the anchorages, while the resin heads remained always undamaged. These outcomes strengthen the confidence in the proposed anchor system.
dc.publisherAmerican Society of Civil Engineers
dc.titleAnchor System for Tension Testing of Large Diameter GFRP Bars
dc.typeJournal Paper
dc.journal.volume13
dc.journal.issue5
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000027
dc.treeJournal of Composites for Construction:;2009:;Volume ( 013 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record