Seismic Behavior of CFT Column and Steel Pile Footings
Date
2011Author
Yan Xiao
Zhongxin Zhang
Jianhua Hu
Sashi K. Kunnath
Pengxin Guo
Metadata
Show full item recordAbstract
In this study, two column and pile-footing models consisting of concrete-filled steel tube (CFT) columns, reinforced concrete footings, and steel H-piles were designed and constructed at approximately one-fifth scale. The experimental differences between the two models were in the design details of the CFT column-to-footing connections. One connection consisted of welded studs, and the other used a base plate and stiffeners. The two models were tested in a vertical cantilever condition with cyclic horizontal forces and a constant axial load applied to the top of the column. The model footings were supported on 16 model steel H-piles simulating the pile foundation. Under imposed horizontal displacement, the two models with different CFT-to-pile-cap connection details demonstrated satisfactory cyclic behavior, with the development of full plastic hinges at the bottom of the columns. Strut-and-tie modeling analysis was carried out to show the force-resisting mechanism in the reinforced concrete footing. The study also validated a new design detail for the anchorage of steel H-piles to pile caps.