• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Architectural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Architectural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Review of Transverse Reinforcement Requirements for Precast Load-Bearing Wall Panels with Large Openings under Compression

    Thumbnail
    View/Open
    %28asce%29ae%2E1943-5568%2E0000141.pdf (3.835Mb)
    Date
    2014
    Author
    Mohamed
    Elkady
    George
    Morcous
    Maher K.
    Tadros
    Metadata
    Show full item record
    Abstract
    Precast concrete load-bearing wall panels have been used for decades with unparalleled success due to their architectural versatility, thermal insulation, ease of production and erection, and structural performance. According to the current building code, structural walls do not need transverse ties if the vertical reinforcement ratio is less than 1% or when vertical reinforcement is not required as compression reinforcement. Also, minimum reinforcement requirements do not apply to structural walls with an average effective prestress of 1,551 kPa (225 psi) or greater. Elimination of transverse ties in structural precast walls simplifies the production of the panels. The presence of large openings in precast walls is very common in the design of modern buildings. This results in a significant reduction of the panel cross section. Most designers tend to design the remaining portion of the panel cross section as a column and not a wall, which requires minimum transverse ties according to the current building code in the United States. The requirement could complicate wall detailing and reduce the efficiency and economy of panel fabrication. This paper summarizes the literature review conducted to determine when precast load-bearing walls should be designed as columns/walls with respect to transverse reinforcement. The requirements of transverse reinforcement in walls and columns in various building codes were studied, and design recommendations were made.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/56141
    Collections
    • Journal of Architectural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV