dc.description.abstractPerformance of near-surface mounted (NSM) bars as additional reinforcement in strengthening of existing reinforced-concrete construction largely depends on the development capacity of the bar inside the groove. This is controlled primarily by the surface characteristics of the bar and its interaction with the surrounding groove filler and the cover concrete. In this paper, the bond strength of short NSM-bar anchorages is explored experimentally, using a modified eccentric pullout test specimen designed to alleviate some of the deficiencies associated with bond testing. A total of 45 tests were conducted to study the influence of the most important technological parameters of this upgrading method, namely the groove dimensions, the embedment length, and the surface pattern of the bars. NSM bars were