Show simple item record

dc.contributor.authorWilliam D. Tape
dc.contributor.authorJohn B. Kennedy
dc.contributor.authorMurty K. Madugula
dc.date.accessioned2017-05-08T21:30:56Z
dc.date.available2017-05-08T21:30:56Z
dc.date.copyrightFebruary 2007
dc.date.issued2007
dc.identifier.other%28asce%291090-0268%282007%2911%3A1%2891%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54426
dc.description.abstractThe current methods of connecting the flanges of precast double tee members, and their respective short comings in specific situations, are described. A new carbon fiber-reinforced polymer (CFRP) flange-to-flange connection is proposed to eliminate the problems associated with repair requirements for the current connections. Design expressions for the currently used mechanical anchorage and the proposed CFRP connection are presented. A comparative calculation for the two systems is given.
dc.publisherAmerican Society of Civil Engineers
dc.titleProposed Design of a CFRP Flange-to-Flange Connection for Precast Prestressed Double Tee Systems
dc.typeJournal Paper
dc.journal.volume11
dc.journal.issue1
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2007)11:1(91)
dc.treeJournal of Composites for Construction:;2007:;Volume ( 011 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record