Show simple item record

dc.contributor.authorT. Yu
dc.contributor.authorY. L. Wong
dc.contributor.authorJ. G. Teng
dc.contributor.authorS. L. Dong
dc.contributor.authorE. S. Lam
dc.date.accessioned2017-05-08T21:30:54Z
dc.date.available2017-05-08T21:30:54Z
dc.date.copyrightOctober 2006
dc.date.issued2006
dc.identifier.other%28asce%291090-0268%282006%2910%3A5%28443%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54399
dc.description.abstractThis paper presents the results of an experimental study on the flexural behavior of a new type of hybrid FRP-concrete-steel member as well as results from a corresponding theoretical model based on the plane section assumption and the fiber element approach. This new type of hybrid member is in the form of a double-skin tube, composed of a steel inner tube and an FRP outer tube with a concrete infill between the two tubes, and may be employed as columns or beams. The parameters examined in this study include the section configuration, the concrete strength, and the thicknesses of the steel tube and the FRP tube, respectively. The results presented in this paper show that these hybrid beams have a very ductile response because the compressive concrete is confined by the FRP tube and the steel tube provides ductile longitudinal reinforcement. The beams' flexural response, including the flexural stiffness, ultimate load, and cracking, can be substantially improved by shifting the inner steel tube toward the tension zone or by providing FRP bars as additional longitudinal reinforcement. The predictions from the theoretical model are in reasonably close agreement with the test results. Differences between the test and predicted results arise from factors not considered in the theoretical model, including the existence of a strain gradient in the confined concrete, concentrations of cracks and the slips between the concrete and the two tubes; these are issues to be accounted for in the development of a more accurate model in the future.
dc.publisherAmerican Society of Civil Engineers
dc.titleFlexural Behavior of Hybrid FRP-Concrete-Steel Double-Skin Tubular Members
dc.typeJournal Paper
dc.journal.volume10
dc.journal.issue5
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2006)10:5(443)
dc.treeJournal of Composites for Construction:;2006:;Volume ( 010 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record