Show simple item record

dc.contributor.authorRagi Aly
dc.contributor.authorBrahim Benmokrane
dc.contributor.authorUsama Ebead
dc.date.accessioned2017-05-08T21:30:53Z
dc.date.available2017-05-08T21:30:53Z
dc.date.copyrightAugust 2006
dc.date.issued2006
dc.identifier.other%28asce%291090-0268%282006%2910%3A4%28287%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54379
dc.description.abstractIn the case of heavily reinforced concrete structural members, bundled bars are required rather than spaced bars. The use of spliced bundled bars is necessary when available bar lengths are limited. No design recommendations regarding the use of bundled or spliced bundled FRP bars are available. The results of four-point flexural testing of nine concrete beams reinforced with spliced bundled CFRP bars are presented herein. The effects of the type of bundle and splice length on the bond strength of bundled CFRP bars are investigated. Based on the experimental results, a procedure for determining the critical splice length of FRP bars is presented and the corresponding values of bond stresses can be predicted. Moreover, the ultimate strength analysis method is used to predict the maximum stress in spliced bundled CFRP bars. Finally, comparisons with the existing recommendations regarding the use of bundled steel bars and the recommended modifications for bundled CFRP bars are presented.
dc.publisherAmerican Society of Civil Engineers
dc.titleTensile Lap Splicing of Bundled CFRP Reinforcing Bars in Concrete
dc.typeJournal Paper
dc.journal.volume10
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2006)10:4(287)
dc.treeJournal of Composites for Construction:;2006:;Volume ( 010 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record