Acoustic Emission Damage Assessment of Steel/CFRP Bonds for Rehabilitation
Date
2006Author
Fabio Matta
Piervincenzo Rizzo
Vistasp M. Karbhari
Francesco Lanza di Scalea
Metadata
Show full item recordAbstract
The use of adhesively bonded carbon fiber reinforced polymer (CFRP) laminates is increasingly being considered for the rehabilitation of metallic structures. The effective structural monitoring of steel/CFRP adhesive joints is of critical importance to assess the design service performance of the system, which ultimately depends on the bond damage tolerance at the load transfer regions. In the present study laboratory static and fatigue tests were conducted on steel/CFRP skin doubler and double strap joint specimens, which were monitored using the acoustic emission (AE) technique. The characteristics of the AE signals were correlated with the mechanical response of the samples, in order to understand the AE response associated with the accumulation of bond damage. One-dimensional source location was also performed to examine the initiation and the development of the disbond. The results show that AE parameter-based analysis is an effective nondestructive evaluation tool for bond damage detection and area location.