| dc.contributor.author | Radhouane Masmoudi | |
| dc.contributor.author | Ali Zaidi | |
| dc.contributor.author | Patrick Gérard | |
| dc.date.accessioned | 2017-05-08T21:30:47Z | |
| dc.date.available | 2017-05-08T21:30:47Z | |
| dc.date.copyright | October 2005 | |
| dc.date.issued | 2005 | |
| dc.identifier.other | %28asce%291090-0268%282005%299%3A5%28377%29.pdf | |
| dc.identifier.uri | http://yetl.yabesh.ir/yetl/handle/yetl/54324 | |
| dc.description.abstract | Fiber reinforced polymers (FRPs) have a thermal expansion in the transverse direction much higher than in the longitudinal direction and also higher than the thermal expansion of hardened concrete. The difference between the transverse coefficient of thermal expansion of FRP bars and concrete may cause splitting cracks within the concrete under temperature increase and, ultimately, failure of the concrete cover if the confining action of concrete is insufficient. This paper presents the results of an experimental investigation to analyze the effect of the ratio of concrete cover thickness to FRP bar diameter | |
| dc.publisher | American Society of Civil Engineers | |
| dc.title | Transverse Thermal Expansion of FRP Bars Embedded in Concrete | |
| dc.type | Journal Paper | |
| dc.journal.volume | 9 | |
| dc.journal.issue | 5 | |
| dc.journal.title | Journal of Composites for Construction | |
| dc.identifier.doi | 10.1061/(ASCE)1090-0268(2005)9:5(377) | |
| dc.tree | Journal of Composites for Construction:;2005:;Volume ( 009 ):;issue: 005 | |
| dc.contenttype | Fulltext | |