Show simple item record

dc.contributor.authorGray Mullins
dc.contributor.authorRajan Sen
dc.contributor.authorKwangsuk Suh
dc.contributor.authorDanny Winters
dc.date.accessioned2017-05-08T21:30:44Z
dc.date.available2017-05-08T21:30:44Z
dc.date.copyrightApril 2005
dc.date.issued2005
dc.identifier.other%28asce%291090-0268%282005%299%3A2%28136%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54297
dc.description.abstractThis paper presents an overview of a demonstration project in which corroding prestressed piles located in tidal waters were wrapped underwater using carbon and glass fiber-reinforced polymer material. An innovative instrumentation scheme was developed to allow assessment of the prewrap and postwrap corrosion state using linear polarization. This system is simple to install and eliminates the need for wiring or junction boxes. The underwater wrap used a unique water-activated urethane resin system that eliminated the need for cofferdam construction. Linear polarization measurements taken before and after wrapping indicate that the corrosion rate in the wrapped specimens is consistently lower than those in its unwrapped counterpart. These preliminary findings are encouraging and suggest that underwater wrapping without cofferdam construction may provide a cost-effective solution for pile repair.
dc.publisherAmerican Society of Civil Engineers
dc.titleUnderwater Fiber–Reinforced Polymers Repair of Prestressed Piles in the Allen Creek Bridge
dc.typeJournal Paper
dc.journal.volume9
dc.journal.issue2
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2005)9:2(136)
dc.treeJournal of Composites for Construction:;2005:;Volume ( 009 ):;issue: 002
dc.contenttypeFulltext