Show simple item record

dc.contributor.authorTim Stratford
dc.contributor.authorGiovanni Pascale
dc.contributor.authorOdine Manfroni
dc.contributor.authorBarbara Bonfiglioli
dc.date.accessioned2017-05-08T21:30:40Z
dc.date.available2017-05-08T21:30:40Z
dc.date.copyrightOctober 2004
dc.date.issued2004
dc.identifier.other%28asce%291090-0268%282004%298%3A5%28434%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54261
dc.description.abstractThis paper investigates strengthening masonry walls using glass-fiber reinforced polymer (GFRP) sheets. An experimental research program was undertaken. Both clay and concrete brick specimens were tested, with and without GFRP strengthening. Single-sided strengthening was considered, as it is often not practicable to apply the reinforcement to both sides of a wall. Static tests were carried out on six masonry panels, under a combination of vertical preload, and in-plane horizontal shear loading. The mechanisms by which load was carried were observed, varying from the initial, uncracked state, to the final, fully cracked state. The results demonstrate that a significant increase of the in-plane shear capacity of masonry can be achieved by bonding GFRP sheets to the surface of masonry walls. The experimental data were used to assess the effectiveness of the GFRP strengthening, and suggestions are made to allow the test results to be used in the design of sheet GFRP strengthening for masonry structures.
dc.publisherAmerican Society of Civil Engineers
dc.titleShear Strengthening Masonry Panels with Sheet Glass-Fiber Reinforced Polymer
dc.typeJournal Paper
dc.journal.volume8
dc.journal.issue5
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2004)8:5(434)
dc.treeJournal of Composites for Construction:;2004:;Volume ( 008 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record