• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Retrofit of a Three-Span Slab Bridge with Fiber Reinforced Polymer Systems—Testing and Rating

    Thumbnail
    View/Open
    %28asce%291090-0268%282004%298%3A3%28241%29.pdf (766.3Kb)
    Date
    2004
    Author
    Bahram M. Shahrooz
    Serpil Boy
    Metadata
    Show full item record
    Abstract
    A 45-year old, three-span reinforced concrete slab bridge with insufficient capacity was retrofitted with 76.2- and 127-mm wide bonded carbon fiber-reinforced polymer (FRP) plates, 102-mm wide bonded carbon FRP plates with mechanical anchors at the ends, and bonded carbon FRP fabrics. The use of four systems in one bridge provided a unique opportunity to evaluate field installation issues and to examine the long-term performance of each system under identical traffic and environmental conditions. Using controlled truckload tests, the response of the bridge before retrofitting, shortly after retrofitting, and after one year of service was measured. The stiffness of the FRP systems was small in comparison to the stiffness of the bridge deck, and accordingly the measured deflections did not change noticeably after retrofitting. The measured strains suggest participation of the FRP systems, and more importantly, the strength of the retrofitted bridge was increased. A detailed 3D finite-element model of the original and retrofitted bridge was developed and calibrated based on the measured deflections. The model was used to predict more accurately the demands for computing the rating factors. The addition of FRP plates and fabrics led to a 22% increase in the rating factor and corresponding load limits. During a one-year period, traffic loading and environmental exposure did not apparently affect the performance of the FRP systems. The increased capacity and acceptable performance of the FRP systems enabled the engineers to remove the load limits in order to resume normal traffic. Future tests are necessary to monitor the long-term behavior of the FRP systems.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/54236
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV