Show simple item record

dc.contributor.authorYeol Choi
dc.contributor.authorRobert L. Yuan
dc.date.accessioned2017-05-08T21:30:35Z
dc.date.available2017-05-08T21:30:35Z
dc.date.copyrightNovember 2003
dc.date.issued2003
dc.identifier.other%28asce%291090-0268%282003%297%3A4%28356%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54205
dc.description.abstractThis paper describes an experimental investigation into the time-dependent deformation of pultruded glass fiber reinforced polymer (GFRP) composite columns under an axial-compressive loading at the environmental controlling room with a constant temperature and relative humidity. Tests were conducted on two types of cross-sectional columns: closed-cross section such as square tube (box) and opened-cross section such as wide flange. Both types of columns were 1,200 mm in length, and had cross-sectional dimensions of 102 mm×102 mm and with a 6.4 mm thickness. A total of eight GFRP composite columns were tested at four different stress levels; 20, 30, 40, and 50% of the average ultimate compressive strength from the short-term column tests. The experiments were conducted for approximately 2,500 h with an individual hydraulic loading jack system. The test results indicate that Findley’s power law model can be successfully used to predict time-dependent deformation of GFRP composite columns, and the time-dependent compressive elastic modulus would be decreased as much as 30% of initial value over a 50-year period.
dc.publisherAmerican Society of Civil Engineers
dc.titleTime-Dependent Deformation of Pultruded Fiber Reinforced Polymer Composite Columns
dc.typeJournal Paper
dc.journal.volume7
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2003)7:4(356)
dc.treeJournal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record