dc.contributor.authorLarry C. Muszynski
dc.contributor.authorMichael R. Purcell
dc.date.accessioned2017-05-08T21:30:33Z
dc.date.available2017-05-08T21:30:33Z
dc.date.copyrightMay 2003
dc.date.issued2003
dc.identifier.other%28asce%291090-0268%282003%297%3A2%2898%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54182
dc.description.abstractTwo concrete structures and three air-entrained concrete (AEC) masonry walls were subjected to two, high explosive detonations. The concrete structures were placed at a stand-off distance such that medium damage was expected. The stand-off distance of the AEC-masonry walls was reduced on each successive detonation until breaching occurred. The two concrete structures retrofitted with composite materials were subjected to air-blast loading at a stand-off distance of approximately 14.6 m. The structures were constructed such that each long side of the structure contained a wall retrofitted with a composite material and a wall left bare as a control. Both concrete structures exhibited less residual displacement on the walls strengthened with composite materials than the bare control walls.
dc.publisherAmerican Society of Civil Engineers
dc.titleUse of Composite Reinforcement to Strengthen Concrete and Air-Entrained Concrete Masonry Walls against Air Blast
dc.typeJournal Paper
dc.journal.volume7
dc.journal.issue2
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2003)7:2(98)
dc.treeJournal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 002