dc.description.abstractStudies were conducted to understand the galvanic interactions between CFRP and steel in chloride-contaminated concrete. CFRP-pultruded rod samples (6 mm in diameter), #3 deformed plain rebar (PR, uncoated), and #4 epoxy-coated reinforcing (ECR) steel bars were tested. After 350 days, potential measurements of CFRP and steel samples in chloride-contaminated concrete were −200 and −600 mV (versus CSE), respectively. These results confirm that chloride contamination in concrete could allow galvanic corrosion between CFRP and steel. The measured galvanic current densities were up to 0.7 and 100 μA/m
dc.publisherAmerican Society of Civil Engineers
dc.titleGalvanic Corrosion of Steel in Contact with Carbon-Polymer Composites. II: Experiments in Concrete
dc.typeJournal Paper
dc.journal.volume6
dc.journal.issue2
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2002)6:2(116)
dc.treeJournal of Composites for Construction:;2002:;Volume ( 006 ):;issue: 002