Show simple item record

dc.contributor.authorAndrés A. Torres-Acosta
dc.date.accessioned2017-05-08T21:30:31Z
dc.date.available2017-05-08T21:30:31Z
dc.date.copyrightMay 2002
dc.date.issued2002
dc.identifier.other%28asce%291090-0268%282002%296%3A2%28112%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54135
dc.description.abstractGalvanic corrosion is a possible form of deterioration when carbon fiber-reinforced polymer (CFRP) composites and steel are in direct contact in concrete, as in stirrups tied to prestressing CFRP tendons. Laboratory experiments were performed to determine the magnitude of galvanic currents that may take place as a consequence. Preliminary results show little galvanic corrosion of steel (between
dc.publisherAmerican Society of Civil Engineers
dc.titleGalvanic Corrosion of Steel in Contact with Carbon-Polymer Composites. I: Experiments in Mortar
dc.typeJournal Paper
dc.journal.volume6
dc.journal.issue2
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(2002)6:2(112)
dc.treeJournal of Composites for Construction:;2002:;Volume ( 006 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record