Show simple item record

dc.contributor.authorM. R. Ehsani
dc.contributor.authorH. Saadatmanesh
dc.contributor.authorJ. I. Velazquez-Dimas
dc.date.accessioned2017-05-08T21:30:21Z
dc.date.available2017-05-08T21:30:21Z
dc.date.copyrightAugust 1999
dc.date.issued1999
dc.identifier.other%28asce%291090-0268%281999%293%3A3%28134%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54036
dc.description.abstractUnreinforced masonry (URM) buildings perform poorly under seismic forces and have been identified as the main cause of loss of life in recent earthquakes. Many of these structures fail in out-of-plane bending due to the lack of reinforcement. In this study, the experimental results from three half-scale unreinforced brick walls retrofitted with vertical composite strips are presented. The specimens were subjected to cyclic out-of-plane loading. Five reinforcement ratios and two different glass fabric composite densities were investigated. The mode of failure is controlled by tensile failure when wider and lighter composite fabrics are used and by delamination when stronger ones are used. The tested specimens were capable of supporting a lateral load up to 32 times the weight of the wall. A deflection as much as 2% of the wall height was measured. Although both URM walls and composite strips behave in a brittle manner, the combination resulted in a system capable of dissipating some energy. Retrofitting URM walls with composite strips proved to be a good and reliable strengthening alternative.
dc.publisherAmerican Society of Civil Engineers
dc.titleBehavior of Retrofitted URM Walls under Simulated Earthquake Loading
dc.typeJournal Paper
dc.journal.volume3
dc.journal.issue3
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(1999)3:3(134)
dc.treeJournal of Composites for Construction:;1999:;Volume ( 003 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record