Show simple item record

dc.contributor.authorIoan Gergely
dc.contributor.authorChris P. Pantelides
dc.contributor.authorRalph J. Nuismer
dc.contributor.authorLawrence D. Reaveley
dc.date.accessioned2017-05-08T21:30:18Z
dc.date.available2017-05-08T21:30:18Z
dc.date.copyrightNovember 1998
dc.date.issued1998
dc.identifier.other%28asce%291090-0268%281998%292%3A4%28165%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/54012
dc.description.abstractThe application of carbon fiber composite jackets for the three columns and cap beam of an existing concrete bridge pier was performed in September 1996. The evaluation of the pier in the as-is condition, the rehabilitation objectives, and the composite wrap design are presented. A bilinear stress-strain curve for the confinement model of circular and rectangular concrete sections with fiber-reinforced plastic composite jackets is used for performing pushover analyses. In addition, a comparison is made between analytical results and full-scale experiments. It was found that the shear capacity of the cap beam and columns and the ductility of the pier were improved significantly.
dc.publisherAmerican Society of Civil Engineers
dc.titleBridge Pier Retrofit Using Fiber-Reinforced Plastic Composites
dc.typeJournal Paper
dc.journal.volume2
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)1090-0268(1998)2:4(165)
dc.treeJournal of Composites for Construction:;1998:;Volume ( 002 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record