Show simple item record

dc.contributor.authorUrsula Obst
dc.contributor.authorThomas Schwartz
dc.date.accessioned2017-05-08T21:30:04Z
dc.date.available2017-05-08T21:30:04Z
dc.date.copyrightApril 2007
dc.date.issued2007
dc.identifier.other%28asce%291090-025x%282007%2911%3A2%2878%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/53866
dc.description.abstractIn the last few years microbial activities within the drinking water distribution network have gained more and more attention. Hygienic problems, harassment with odor and bad taste, and even material deterioration are the consequences of microbial life in the pipes. The growth of adhesive bacteria, so-called biofilms, seems to be the main reason for the problems mentioned above. Bacteria settling down as biofilm develop specific characteristics concerning persistence, increased metabolic activities, and sheltering opportunistic microbes. Moreover, biofilms are difficult to detect and to identify by conventional microbiological methods. In the distribution network of a German city biofilms were sampled and characterized by sensitive molecular biological and biochemical techniques. The correlation between different pipe materials and biofilm growth could be followed up over the time. The source and quality of the raw water influenced the population diversity as well as the metabolic activity of the biofilms. Opportunistic and pathogenic bacteria such as enterococci, mycobacteria, and legionellae were obviously sheltered and may persist within the biofilms, even though rarely. The specific characteristics of biofilms increased the tolerance to disinfection steps and initiated the microbial stress and repair responses. Besides that, a horizontal gene transfer between different biofilm bacteria has to be considered as potentially risky, especially with surface water as a raw water source. As a conclusion, monitoring of biofilms in distribution networks is technically as important as conventional hygienic control to avoid harassment and to manipulate inevitable biofilms to support good water quality.
dc.publisherAmerican Society of Civil Engineers
dc.titleMicrobial Characteristics of Water Distribution: Compiled Investigations in a German Drinking Water Distribution System
dc.typeJournal Paper
dc.journal.volume11
dc.journal.issue2
dc.journal.titlePractice Periodical of Hazardous, Toxic, and Radioactive Waste Management
dc.identifier.doi10.1061/(ASCE)1090-025X(2007)11:2(78)
dc.treePractice Periodical of Hazardous, Toxic, and Radioactive Waste Management:;2007:;Volume ( 011 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record