Simplified AASHTO Load and Resistance Factor Design Girder Live Load Distribution in Illinois
Date
2004Author
Daniel H. Tobias
Ralph E. Anderson
Salah Y. Khayyat
Zeyn B. Uzman
Kevin L. Riechers
Metadata
Show full item recordAbstract
Illinois began full transition to the American Association of State Highway and Transportation Officials load and resistance factor design (LRFD) bridge design specifications from the traditional load factor design code or standard specifications in 2002. To facilitate implementation of the new specification, engineers from the Illinois Department of Transportation undertook a series of investigations. The studies focused on interpretation of LRFD for the design of typical bridges in Illinois and the simplification of its procedures for determination of live load lane distributions to primary superstructure girders. Some important presented results from the conducted investigations are believed not only relevant to bridge design in Illinois, but to other states and jurisdictions which employ or will employ LRFD in the near future. The initial simplifications and interpretations focused on concrete deck-on-steel girder bridges and were subsequently expanded to include concrete deck-on-prestressed concrete girder structures. These types of structures comprise a large portion of Illinois’ inventory. Illinois Department of Transportation engineers continue to build on the studies described in the paper such that policies and procedures for other types of typical bridges can be formulated.