    This paper presents the results of mock-up cable erection tests for the Yong Jong Grand Bridge, Inchon, Korea. The Grand Bridge includes the world's first self-anchored spatial suspension bridge whose main cable planes are inclined in the transverse direction. Cable erection problems were expected to occur at the pylon saddle and the splay band due to the self-anchored cable system and the difference between the erection and completed layout of the main cable. The mock-up tests were performed prior to actual cable erection. Through the tests, cable erection problems at the saddle, lateral displacement, and bending of the wires inside the saddle were identified, and measures to deal with the problems were devised and tested. The tested measures were successfully implemented for the construction of the bridge.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/50540
    Collections
    • Journal of Bridge Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV