Cable Erection Test at Pylon Saddle for Spatial Suspension Bridge
Abstract
This paper presents the results of mock-up cable erection tests for the Yong Jong Grand Bridge, Inchon, Korea. The Grand Bridge includes the world's first self-anchored spatial suspension bridge whose main cable planes are inclined in the transverse direction. Cable erection problems were expected to occur at the pylon saddle and the splay band due to the self-anchored cable system and the difference between the erection and completed layout of the main cable. The mock-up tests were performed prior to actual cable erection. Through the tests, cable erection problems at the saddle, lateral displacement, and bending of the wires inside the saddle were identified, and measures to deal with the problems were devised and tested. The tested measures were successfully implemented for the construction of the bridge.