Stability Analysis of Box-Girder Cable-Stayed Bridges
Abstract
The objective of this study is to investigate the stability characteristics of box-girder cable-stayed bridges by three-dimensional finite-element methods. Cable-stayed bridges have many design parameters, because they have a lot of redundancies, especially for long-span bridges. Cable-stayed bridges exhibit several nonlinear behaviors concurrently under normal design loads because of large displacements; the interaction among the pylons, the stayed cables, and the bridge deck; the strong axial and lateral forces acting on the bridge deck and pylons; and cable nonlinearity. A typical two-lane, three-span, steel box-girder cable-stayed bridge superstructure was selected for this paper. The numerical results indicate that, if the ratio of the main span length with respect to the total span length,