Show simple item record

dc.contributor.authorKelli S. Hart
dc.contributor.authorBrad D. Lee
dc.contributor.authorPhilip J. Schoeneberger
dc.contributor.authorDonald P. Franzmeier
dc.contributor.authorPhillip R. Owens
dc.contributor.authorDouglas R. Smith
dc.date.accessioned2017-05-08T21:24:23Z
dc.date.available2017-05-08T21:24:23Z
dc.date.copyrightAugust 2008
dc.date.issued2008
dc.identifier.other%28asce%291084-0699%282008%2913%3A8%28665%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/50230
dc.description.abstractConcerns from local health departments regarding premature septic system failure (less than 1 year from installation) has led to an investigation of septic system soil absorption field design parameters in northeast Indiana. The objective of this study was to compare the loading rate based on field measured saturated hydraulic conductivity
dc.publisherAmerican Society of Civil Engineers
dc.titleComparison of Field Measured Soil Absorption Field Loading Rates and Loading Rates Estimated from Soil Morphologic Properties
dc.typeJournal Paper
dc.journal.volume13
dc.journal.issue8
dc.journal.titleJournal of Hydrologic Engineering
dc.identifier.doi10.1061/(ASCE)1084-0699(2008)13:8(665)
dc.treeJournal of Hydrologic Engineering:;2008:;Volume ( 013 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record