Show simple item record

dc.contributor.authorDavid V. Rosowsky
dc.contributor.authorScott D. Schiff
dc.date.accessioned2017-05-08T21:21:53Z
dc.date.available2017-05-08T21:21:53Z
dc.date.copyrightJune 1999
dc.date.issued1999
dc.identifier.other%28asce%291076-0431%281999%295%3A2%2837%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/48563
dc.description.abstractThe design of mechanical fasteners such as nails and screws used in light-frame construction typically is based on a single assumed loading mechanism or failure limit state, either withdrawal load or lateral load. Observations of failed structures, both in the field and in the laboratory, have confirmed that simple mechanical fasteners in light-frame construction often exhibit combined (lateral and withdrawal) failure modes. In recognizing the potential for combined loads, the 1997
dc.publisherAmerican Society of Civil Engineers
dc.titleCombined Loads on Sheathing to Framing Fasteners in Wood Construction
dc.typeJournal Paper
dc.journal.volume5
dc.journal.issue2
dc.journal.titleJournal of Architectural Engineering
dc.identifier.doi10.1061/(ASCE)1076-0431(1999)5:2(37)
dc.treeJournal of Architectural Engineering:;1999:;Volume ( 005 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record