dc.contributor.authorDuen Ho
dc.date.accessioned2017-05-08T21:21:43Z
dc.date.available2017-05-08T21:21:43Z
dc.date.copyrightSeptember 1995
dc.date.issued1995
dc.identifier.other%28asce%291076-0431%281995%291%3A3%28121%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/48449
dc.description.abstractTemperatures in the walls and roofs of an experimental shed were measured. An “average” mathematical model was established for the determination of heat flow through wall and roof elements with different surface finishes. The input meteorological data and parameters used in calculation are discussed. The measured data were used to calibrate the model and check the assumptions involved. Based on the established model, heat flow through wall and roof elements and efficiency of different surface finishes are compared. The thermal inertia of a 150-mm-thick concrete wall is significant. Heat transmitted through a wall also depends greatly on the color of its surface. The insulation layers reduce heat flow into the interior and increase considerably the thermal inertia of a roof. The study focused on the summer period.
dc.publisherAmerican Society of Civil Engineers
dc.titleTemperature Distribution in Walls and Roofs
dc.typeJournal Paper
dc.journal.volume1
dc.journal.issue3
dc.journal.titleJournal of Architectural Engineering
dc.identifier.doi10.1061/(ASCE)1076-0431(1995)1:3(121)
dc.treeJournal of Architectural Engineering:;1995:;Volume ( 001 ):;issue: 003