• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Tribology
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Tribology
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Optimized Design and Biomechanical Analysis of Novel Hollow-Porous Hip Prosthesis for Enhancing Bone–Implant Interactions

    Thumbnail
    View/Open
    trib-25-1725.pdf (1.619Mb)
    Date
    2026
    Author
    Le, Nam Bich Thi
    Nguyen, Trung Kien
    Phung, Lan Xuan
    Thanh Le, Dat
    Do, Truong
    Metadata
    Show full item record
    Abstract
    Abstract. The increasing demand for total hip arthroplasty, driven by osteoarthritis in the elderly and trauma in younger patients, necessitates implants with high biocompatibility and mechanical longevity. Current metallic implants (titanium, cobalt–chromium) often lead to stress shielding due to their high stiffness compared to human cortical bone, resulting in bone resorption and aseptic loosening. In this study, a porous hip joint structure design is proposed to enhance the load-bearing capacity of the hip joint and mitigate shielding stress after surgery. The hip joint model examined in this article features an improved design, including a hollow head, a porous stem with varying hollow structures and densities, and a stem surrounded by a bone block. The finite element method (based on ansys software) is used to analyze the biomechanical behavior of the artificial hip joint and the interaction between the joint and surrounding bone during the activities of young patients, including daily activities and dynamic movements such as climbing stairs and playing sports. The results presented in this article include stress and deformation distribution on the joint components and the bone. In addition, the sliding distance and contact pressure between the joint components, between the joint and the bone, were also investigated. Wearing mechanics of the liner's surfaces when in contact with the cup and head are also examined. From the results obtained, the study has proposed several hip joint designs that ensure sufficient durability and reduce joint laxity during patient activities.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4316852
    Collections
    • Journal of Tribology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse
    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV