    Influence of Acetabular Cup Elevation Height on Contact and Failure Analysis of Metal-on-Metal Hip Prosthesis Under Mild and Severe Microseparations for Regular and Risky Gait Loads

    Thumbnail
    View/Open
    trib-25-1462.pdf (2.042Mb)
    Date
    2026
    Author
    Nithyaprakash, R.
    Shankar, S.
    Naveen Kumar, R.
    Mithun Krishna, J.
    Thangarasu, S. K.
    Abbas, G.
    Sugunesh, A. P.
    Prakash, Chander
    Pramanik, Alokesh
    Basak, Animesh Kumar
    Manikandan, M.
    Kalayarasan, M.
    Metadata
    Show full item record
    Abstract
    Abstract. Acetabular cup contact stress and failure analysis play a crucial role in estimating the durability of implants. Many studies have focused on the modification of acetabular cup design parameters to improve their longevity. The present study focuses on one such design consideration by varying the acetabular cup elevation height using a global model finite element conceptualization. Acetabular cup elevation height variation of 1, 2, and 3 mm with microseparations of 0.5, 1, 1.5, 2, 2.5, and 3 mm are considered to analyze contact and von Mises stress for the CoCr alloy at a 45 deg cup inclination angle. The peak gait loads of grouped gait activities, namely, A, B, C, and D, consisting of 19 gait loads, are used to estimate the aforesaid stresses. Group C and D gait load activities are very rarely performed by humans in day-to-day activities, while group A and B gait load activities are performed quite often by humans, except for a few gait activities like lifting and carrying loads. Results revealed that a cup elevation height of 3 mm was found to effectively reduce contact stress for microseparation of 2.5 and 3 mm. The 1 mm elevation height showed higher contact stress values for almost all microseparations. From von Mises plots, it is evident that the elevated acetabular cup prevents implant failure even for high microseparation values for gait loads grouped under the A and B categories. For physically demanding gait loads listed in group C and D categories, for all microseparation values, von Mises stress values of the elevated cup showed values higher than the yield stress of the CoCr alloy.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4316838
    Collections
    • Journal of Tribology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV