• Login
    View Item 
    •   DSpace Home
    • ASME
    • ASME Journal of Heat and Mass Transfer
    • View Item
    •   DSpace Home
    • ASME
    • ASME Journal of Heat and Mass Transfer
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental and Numerical Investigation of the Effect of Heater Parameters on the Onset of Nucleate Boiling From Suspended Strip Heaters

    Thumbnail
    View/Open
    ht-25-1132.pdf (2.799Mb)
    Date
    2026
    Author
    Pinto, John
    Murallidharan, Janani Srree
    Iyer, Kannan N.
    Metadata
    Show full item record
    Abstract
    Abstract. The point of onset of nucleate boiling (ONB) is the transition point from convection to boiling. Understanding the variation in ONB with heater parameters, namely, heater width, thickness, material, and subcooling, will help in the effective design of heat transfer systems. The present study aims to develop an understanding of ONB as a function of different heater parameters. An experimental investigation was carried out to determine the effect of heater widths and thicknesses for different material strips, namely, stainless steel 316 (SS 316), nickel, and copper. The main finding of the study is that, with a decrease in heater width, there is a nonlinear increase in the heat flux and wall superheat at ONB. A supplementary computational fluid dynamics (CFD) investigation has been done to understand this behavior, and it is concluded that the variation in the thermal plume movement resulted in the change in average strip temperature. Smaller width strips had relatively stable plumes that completely engulfed the heater, whereas the thermal plume for larger heaters had higher movement and allowed cooling from the sides, resulting in lower average heater temperatures. The heater temperature at ONB is found to be lower for strips with materials having higher conductivity and thickness. The reduction in the lateral thermal resistance is found to be the contributor to this observed decrease. A correlation is arrived at that takes into consideration the effect of heater parameters.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4316670
    Collections
    • ASME Journal of Heat and Mass Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV