• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    An Experimental Investigation of the Effects of Air Ingestion on Subsynchronous Damping Coefficients in an Open Ends Squeeze Film Damper

    Thumbnail
    View/Open
    gtp-25-1573.pdf (1.613Mb)
    Date
    2026
    Author
    Grigat, Nicolas
    Gheller, Edoardo
    Delgado, Adolfo
    Pennacchi, Paolo
    Metadata
    Show full item record
    Abstract
    Abstract. Squeeze film dampers (SFDs) utilize a thin oil film between a nonrotating journal and stationary housing to reduce vibrational amplitudes while crossing critical speeds and improve stability. SFDs may experience air ingestion with certain end seal designs and motion amplitudes, leading to a reduction in damping coefficients. Most research into SFDs focuses on circular, centered orbits (CCOs), meaning the applied excitation consists of one frequency component; however, turbomachines frequently experience excitations containing both synchronous and subsynchronous frequency components. These experiments use a dual-frequency excitation with the smaller frequency varying from 9 to 42 Hz and being labeled as “subsynchronous.” A higher frequency is held constant at 100 Hz and is labeled “synchronous.” One test condition holds the subsynchronous amplitude constant with an amplitude to clearance ratio (r/c) equal to 5%, and the synchronous amplitude ranging from r/c = 5–60%. A second test condition sets both amplitudes to equal values ranging from r/c = 5–30%. Preliminary CCO tests are performed using the synchronous amplitude range outlined above and a frequency range of 10–100 Hz. The 100 Hz tests are used for evaluating the dynamic pressure. All testing is performed using an open-end configuration with a relatively large radial clearance of 279 μm (11 mils). Additional analysis is provided by calculating the average squeeze velocity due to both frequency components and plotting against damping coefficients. The results show a large increase in subsynchronous damping as synchronous amplitude increases, despite the onset of air ingestion. Synchronous amplitude provides the most significant contribution to the squeeze velocity, and the results show that subsynchronous damping increases with significant increases in squeeze velocity.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4316408
    Collections
    • Journal of Engineering for Gas Turbines and Power

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV