• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Age-Related Increases in Graft Tendon Size and Stiffness During Skeletal Growth Enhance Anterior Cruciate Ligament Graft Function and Joint Stability in an Early Adolescent Porcine Model

    Thumbnail
    View/Open
    bio-25-1168.pdf (1.834Mb)
    Date
    2026
    Author
    Zhang, Yukun
    Gurbuz, Kaan
    Chavez-Arellano, Joshua
    Opperman, Logan
    Spang, Jeffrey T.
    Fisher, Matthew B.
    Metadata
    Show full item record
    Abstract
    Abstract. Anterior cruciate ligament (ACL) reconstruction in pediatric patients has a higher graft failure rate compared to adults. Restoring joint stability and reducing graft failure is essential. However, how graft biomechanical properties change with age and affect reconstruction outcomes remains unclear. This study investigated the biomechanical development of porcine flexor tendons across skeletal growth and evaluated how graft size and stiffness influence knee biomechanics in a pediatric porcine model. Flexor tendons (n = 57) were harvested from pigs at 0.5, 1.5, 5, and 9 months of age to measure cross-sectional area (CSA), stiffness, and failure load. ACLs in nine early adolescent porcine knees were reconstructed using both 1.5- and 5-month-old (1.5 mo and 5 mo) grafts and tested under anterior–posterior, compressive, and varus–valgus (VV) loading at 40 deg of flexion using a robotic testing system. ACL and graft forces were calculated, and in situ properties were derived from force–displacement curves. Tendon CSA, stiffness, and failure load increased with age, and stiffness associated with CSA. The CSA of 5 mo tendons was 57% greater than that of 1.5 mo tendons, but stiffness increased only 20%. ACL reconstruction with 5 mo grafts resulted in 29% less anterior–posterior tibial translation and 44% higher graft force compared to 1.5 mo grafts. In situ stiffness of 5 mo grafts was 51% higher than 1.5 mo grafts. These findings highlight the differences between tendon size and biomechanical development, which together contribute to the improvements in joint function following ACL reconstruction.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4316319
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV