Show simple item record

dc.contributor.authorZhang, Jun
dc.contributor.authorLi, Shiyang
dc.contributor.authorHe, Xinxiang
dc.contributor.authorYe, Haojie
dc.contributor.authorWu, Peng
dc.contributor.authorWu, Dazhuan
dc.date.accessioned2026-08-23T08:12:17Z
dc.date.available2026-08-23T08:12:17Z
dc.date.copyright2026/02/01
dc.date.issued2026
dc.identifier.issn0098-2202
dc.identifier.otherfe-25-1071.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316211
dc.description.abstractAbstract. Rotor clocking refers to the circumferential indexing of adjacent rotors, each with an equal number of blades, which impacts tonal noise propagation and the performance of a two-stage axial flow fan. To elucidate the mechanisms by which rotor clocking influences tonal noise in a two-stage axial flow fan, we construct a tonal noise cascade model under the influence of rotor clocking. Utilizing the theory of sound wave superposition, it is determined that the relative phase of sound waves can be controlled through rotor clocking to reduce the amplitude of tonal noise. Through numerical simulations, we visualize the internal flow variations across different rotor clocking models of the fan, investigating pressure fluctuation characteristics in both time and frequency domains, as well as the excitation force characteristics of the second-stage rotor. This study reveals the influence patterns of rotor clocking on flow-induced excitation in the rotor–stator interaction region. Furthermore, by adopting the proper orthogonal decomposition (POD) method, we conduct a quantitative assessment of the primary energy structures in the flow field, analyzing each mode's contribution to the field's energy. Finally, we establish a bridge between internal flow field variations and tonal noise amplitude from both the computational acoustics and acoustic testing perspectives. The research results indicate that the simulated noise spectrum aligns well with the experimental noise spectrum, with tonal noise sound pressure level amplitudes differing by up to approximately 5 dB across different fan rotor clocking models.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Mechanism of the Impact of Rotor Clocking on Tonal Noise of Two-Stage Axial Flow Fan
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue2
dc.journal.titleJournal of Fluids Engineering
dc.identifier.doi10.1115/1.4069700
dc.treeJournal of Fluids Engineering:;2026:;volume( 148 ):;issue:002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record