• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Heat and Moisture Transfer Modeling and Performance Evaluation of Hygroscopic Fabrics for Thermal Comfort Across Different Body Parts in Extreme Heat

    Thumbnail
    View/Open
    jesmdt-26-1004.pdf (1.974Mb)
    Date
    2026
    Author
    Yojitha, Kanathala
    Naik, B. Kiran
    Metadata
    Show full item record
    Abstract
    Abstract. Extreme heat exposure in medical and occupational settings can elevate thermal strain, impair task performance, and increase dehydration risk, particularly when protective clothing restricts ventilation and traps moisture near the skin. This study presents a one-dimensional coupled heat-moisture transfer model to evaluate hygroscopic natural fabrics for wearable cooling applications. Fabric properties for linen, ramie, bamboo, tencel, and hemp were obtained from recent literature, and simulations were performed for ambient temperatures of 38–45 °C, relative humidity (RH) of 90–95%, and wind speeds of 0–10 m/s over a 60 min exposure period. The numerical model describes transient heat conduction and vapor diffusion in the skin and fabric system, with latent cooling effects due to evaporation at the skin interface. The results indicate that the cooling rate is enhanced by wind speed and inversely affected by relative humidity, as the vapor pressure driving force is diminished. Linen fabric presented the highest cooling rate, followed by ramie and bamboo fabrics, with maximum temperature reductions of 5.1 °C, 4.1 °C, and 3.4 °C, respectively, while Tencel and hemp fabrics presented lower rates of 2.5 °C and 2.3 °C. The cooling rate in the body regions is not uniform, with the thigh presenting the maximum temperature reduction of 2.6 °C at 90% RH, while the upper arm and forearm presented lower values at near-saturated conditions. The rate of cooling benefit rose sharply until about 6 m/s and then reached a point of diminishing returns as the speed of airflow further increased. The results of this study can be used as quantitative information for fabric screening and region-targeted design of medical workwear.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4316006
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV