• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Digitalization of the Modified Physical Performance Test

    Thumbnail
    View/Open
    jesmdt-25-1010.pdf (1.496Mb)
    Date
    2026
    Author
    Grosek, Wolfgang
    Roytman, Gregory R.
    Kim, Yeongmi
    Wiznia, Daniel H.
    Wilen, Larry
    Morgado-Vega, Necolle
    Tommasini, Steven M.
    Garza-Rice, Jessica
    Aslam, Rummana
    Metadata
    Show full item record
    Abstract
    Abstract. Physical medicine and rehabilitation clinicians frequently measure the physical functions of their patients with neuromuscular motor dysfunction, such as those recovering from stroke, surgery, or trauma. The Modified Physical Performance Test (MPPT) is a widely accepted measure of physical function. However, the MPPT requires significant time investment from the clinician overseeing the test. Our objective was to create a digital MPPT (dMPPT) based on wearable technology which can be performed without extensive clinician oversight and validate the dMPPT using a clinician directed analogue MPPT (aMPPT). Wearable sensors were developed to capture movements performed in the MPPT. A time score and balance score were calculated for each task. A preliminary clinical trial with ten patients in the inpatient section of a rehabilitation unit was conducted. Patients performed both the aMPPT version without the sensors and the dMPPT with the sensors. We compared scores of the aMPPT with the dMPPT. The Pearson correlation test demonstrated a high (r = 0.99) and significant (p < 0.001) correlation between the aMPPT and dMPPT. Bland–Altman analysis determined that data from all ten participants were within the range defined by the limits of agreement, indicating a high level of practical agreement between the aMPPT and dMPPT. The dMPPT results were significantly correlated and demonstrated a high level of practical agreement with the aMPPT clinician-directed method. Future larger sample clinical trials to validate the dMPPT for clinical use are recommended. With this validation, the dMPPT would allow for more efficient monitoring of patients' physical performance.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315995
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV