dc.description.abstractAbstract. Cables are a key component of power systems. Local defects such as insulation aging and mechanical damage can easily cause serious faults. Impedance spectroscopy analysis has become a research hotspot in defect detection due to its noninvasive nature and sensitivity. However, traditional Fourier transforms have problems such as weak noise suppression, low characteristic resolution, spectral leakage, and insufficient low-frequency resolution, which limit the ability to detect minor defects. To address this limitation and achieve high-precision detection and location of local defects in cables, this article adopts an improved method based on the inverse fast Fourier transform (IFFT). The equivalent time component (2l/v) is extracted from the reflection coefficient spectrum at the beginning of the cable, and the time–frequency resolution is optimized by combining the adaptive window function. The defect characteristic frequency band is enhanced through the frequency-domain weighting algorithm, and the location function DF(x) is constructed to highlight the defect differences. Meanwhile, the signal propagation speed is simulated and measured by comsol software to provide key positioning parameters. Experiments show that this method is not sensitive to the strength of the injected signal (as long as the minimum power is met), but sensitive to the severity of defects. It can accurately locate multiposition defects (such as defects at 10 m, 20 m, and 40 m on a 60 m XLPE cable) and is not affected by cable curls. It is suitable for high-voltage cables and radio frequency (RF) cables with semiconductive layers.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleLocal Defect Detection of Cable Impedance Spectrum by Using Fast Inverse Fourier Transform
dc.typeJournal Paper
dc.journal.volume9
dc.journal.issue2
dc.journal.titleJournal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
dc.identifier.doi10.1115/1.4071266
dc.journal.fristpage59
dc.journal.lastpage63
dc.page5
dc.treeJournal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems:;2026:;volume( 009 ):;issue:002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record