    Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

    Thumbnail
    View/Open
    jesbc-25-1043.pdf (1.386Mb)
    Date
    2026
    Author
    Barber, Emily
    Kishore, Ravi Anant
    Bianchi, Marcus V. A.
    Horton, Travis
    Ruan, Xiulin
    Metadata
    Show full item record
    Abstract
    Abstract. Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. In this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $/m2 or $2646/year for a large 4835 m2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m2 of roof area, thus reducing energy costs by as much as 0.29 $/m2 or $1386/year for a 4835 m2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315935
    Collections
    • ASME Journal of Engineering for Sustainable Buildings and Cities

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV