• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Electronic Packaging
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Electronic Packaging
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Thermal Design and Performance Modeling of a High Compute Density Liquid Cooled Chiller Less Modular Edge Data Center

    Thumbnail
    View/Open
    ep-25-1142.pdf (4.798Mb)
    Date
    2026
    Author
    Tano, Ines-Noelly
    Rasouli, Erfan
    Narayanan, Vinod
    Metadata
    Show full item record
    Abstract
    Abstract. Holistic design of a modular energy-efficient edge datacenter with a compute density of 20 kW/m3 is presented. The datacenter uses a single chiller-less liquid loop to extract heat from server components and reject it to the ambient using a mixture of 25% propylene glycol and water. Heat is extracted from the chips using a multiple unit-cell shedding enhanced (MUSE) cold plate and rejected to the ambient air using a counterflow microchannel polymer heat exchanger (MPHX) dry cooler. The MUSE cold plate consists of a manifold to split flow into parallel paths and a large aspect ratio (7.3:1) microscale pin fin heat sink fabricated using electrochemical additive manufacturing. The counterflow MPHX dry cooler design can provide higher effectiveness than metallic finned tube heat exchangers for identical air side pressure drop. Experiments of the cold plate and MPHX components are presented, and a system model of the cooling loop is developed. At an outdoor temperature of 40 °C, baseline results indicate that optimized liquid and fan flow rates reduce cooling power to 2.1% of compute power for a graphical processing unit (GPU) case temperature of 75 °C and heat flux of 74 W/cm2. Sensitivity studies are performed to assess the impact of improvements in thermal interface material, cold plate convective resistance, and dry cooler air-side heat transfer coefficient on system performance. Results show that, for this heat flux, the thermal interface material (TIM) and dry cooler have the largest impact on the system, with the best-case cooling power being under 1% of compute power.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315877
    Collections
    • Journal of Electronic Packaging

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV