    Design of a Novel Insertion Training System for Central Venous Catheterization

    Thumbnail
    View/Open
    med-25-1253.pdf (1.566Mb)
    Date
    2026
    Author
    Worrall, William
    Moore, Jason Z.
    Metadata
    Show full item record
    Abstract
    Abstract. Central venous catheterization (CVC) is a common medical procedure with a complication rate of over 15%. Current CVC manikin-based simulators lack anatomical variation and objective feedback of user interaction skills, which greatly hinders effective skill acquisition. To address these limitations, a novel CVC insertion training system was developed and integrated with the Advanced Dynamic Haptic Robotic Trainer (DHRT+). This insertion training system contains a sensorized syringe, custom tissue phantom, and a tool detection subsystem, allowing residents to practice nearly the entire CVC procedure with realistic haptics and automated feedback on subcutaneous tool positioning. Five experiments were conducted to assess the haptic fidelity of the sensorized syringe and custom tissue and to evaluate the accuracy of subcutaneous tool detection. Results showed that the sensorized syringe, which detects aspiration and simulates arterial and venous flash, accurately reproduced clinical aspiration forces. The custom tissue phantom provided realistic force feedback during ultrasound (US) compression and needle insertion, comparable to that of commercial tissue phantoms at a substantially lower cost. The color sensors used to distinguish between inserted guidewires and catheters accurately verified tool depth and enabled tool insertion across multiple positions on the tissue surface. Overall, novel CVC insertion training system components were presented that enabled CVC simulation and provided accurate measurement on aspiration, guidewire depth, and catheter depth.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315602
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV