• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comparative Mechanical Behavior of Stainless Steel and Titanium for Pectus Bar Applications

    Thumbnail
    View/Open
    med-25-1044.pdf (1.046Mb)
    Date
    2026
    Author
    Ablordeppey, Eugene
    Ondar, Kyle
    Hezrony, Benjamin
    Brown, Philip
    Metadata
    Show full item record
    Abstract
    Abstract. Stainless steel pectus bars are the go-to material for treating pectus excavatum (PE), a condition characterized by a sunken chest wall. However, 5% of patients develop metal allergies and skin rashes. This study aimed to assess whether titanium is a viable alternative material for these implants, considering its lower risk of allergic reactions and magnetic resonance imaging (MRI) compatibility. Stainless steel (316L) and titanium (CP-Ti) pectus bars were subjected to static and dynamic fatigue testing using MTS testing frame. The static test involved ramp-to-failure four-point bending, where the force was measured until 15 mm of midspan displacement was detected. In the fatigue test, a sinusoidal amplitude of peak (250 N±5 N) and valley (50 N±5 N) was applied to the bars for 1 × 106 cycles at 15 Hz in displacement control. In the static test, both materials showed similar maximum force (p = 0.81), but titanium displayed higher values in plastic deformation (p = 0.0142), total energy (p = 0.0051), and stiffness (p = 0.0051), with relative differences of 16.14%, 3.99%, and 9.44%, respectively. During the fatigue test, titanium showed higher stiffness at 50 N and 250 N, with relative differences of 9.03% and 1.1%, respectively. However, stainless steel had higher values for all other fatigue measurements. Importantly, neither material sustained any noticeable damage after 1 × 106 cyclic loads. The study concluded that both materials perform equally well, but titanium's reduced risk of allergic reactions and MRI compatibility make it a favorable option for patients with metal allergies.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315599
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV