• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    AR-CPR 2.0: Validation of the Accuracy and Precision of a Wearable Coaching System for Improving Chest Compression Performance

    Thumbnail
    View/Open
    med-25-1094.pdf (1.084Mb)
    Date
    2026
    Author
    Kleinman, Keith
    Dean, James L.
    Yu, Erika
    Schreurs, Blake A.
    Jeffers, Justin M.
    Metadata
    Show full item record
    Abstract
    Abstract. Pediatric cardiopulmonary resuscitation (CPR) quality remains inconsistent, with low adherence to guideline-recommended compression rate and depth. Augmented reality cardiopulmonary resuscitation (AR-CPR) is an augmented reality feedback system designed to improve CPR performance using real-time, in-view coaching via smart glasses. To validate the accuracy and precision of the AR-CPR system in measuring chest compression rate and depth across clinically relevant ranges, we tested AR-CPR using a programable oscillation platform at five rates (100–140 compressions per minute (CPM)) and four depths (4.0–5.5 cm), and with the Stryker LUCAS3 device at 102 CPM and 5.3 cm. A total of 473 compressions (slide test) and 559 compressions (LUCAS3 test) were analyzed. Statistical methods included intraclass correlation coefficients (ICC[2,1]), paired t-tests, Bland–Altman analysis, root-mean-square error (RMSE), kernel density estimation for error distribution, and group error modeling to estimate clinical thresholds (±2.5 CPM, ±0.5 cm). Linearity was assessed via linear regression. The AR-CPR system demonstrated high accuracy and reliability in 473 simulated and 559 mechanical compressions. Mean biases were minimal for rate (−0.48, −0.44 CPM) and depth (+0.39, +0.59 cm), with excellent ICCs (0.997 rate, 0.944 depth). Errors were normally distributed, with <7% exceeding clinically relevant thresholds. R2 values (0.994 rate, 0.903 depth) confirmed strong linear agreement with reference values. AR-CPR reliably measured compression rate and depth with high accuracy and precision across variable and fixed testing conditions. Its portability, real-time feedback, and robust signal processing support its potential for improving pediatric resuscitation training and clinical performance.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315559
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV