Show simple item record

dc.contributor.authorIbrahim, Abdelmaged H.
dc.contributor.authorHussein, Mahmoud A.
dc.contributor.authorAbdel Aziz, Mostafa M.
dc.contributor.authorKayed, Hatem
dc.contributor.authorAbou-Arab, Tharwat W.
dc.contributor.authorHabib, Mohamed A.
dc.contributor.authorKhedr, Alaa M.
dc.contributor.authorNemitallah, Medhat A.
dc.date.accessioned2026-08-23T07:40:55Z
dc.date.available2026-08-23T07:40:55Z
dc.date.copyright2026/01/01
dc.date.issued2026
dc.identifier.issn2997-0253
dc.identifier.otherjerta-25-1342.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315442
dc.description.abstractAbstract. The stability, macrostructure, and emissions of diffusion-assisted premixed oxy-CNG (compressed natural gas) flames, stabilized over a burner of a perforated plate with a diffusion central hole, were experimentally investigated in a model gas turbine combustor. Four sets of experiments were conducted with the first three sets characterizing stability maps of the combustor, in terms of upper and lower blow-off limits, in the Φ–Reoxidizer domain, over ranges of fuel diffusion percentage (DP: 0%, 5%, 10% and 15%) at different oxygen fractions (OFs) of 29%, 32% and 36%. The fourth set characterizes the combustor near stoichiometry (Φ = 0.85) stability maps, in terms of flashback and blow-off limits, in the OF–Reoxidizer domain over ranges of the same range of DPs. The results showed better flame stability with extended upper and lower blow-off limits at higher DPs and OFs because of the excess CNG ejecting in the burner and high kinetics at high O2 concentrations. Overall flame length was elongated with OF; however, adding a diffusion flame at high DP fades the outer flame of the cone due to high O2 consumption and low reactivity. At Φ = 0.85, close to stoichiometry, operability of the combustor was constrained within the OF range of 25% (at blowout) to 46% (at flashback). The operating OF value should not surpass 36% at a DP of 15% in order to prevent flashback. The developments of concentrations of CO, CO2, and O2 are presented within the combustor domain for better characterization of the flame stratification.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffects of Diffusion Fuel and Oxygen Fraction on Macrostructure, Operability Limits, and Emissions of Premixed Natural-Gas Oxy-Flames Over a Perforated Plate Burner
dc.typeJournal Paper
dc.journal.volume2
dc.journal.issue1
dc.journal.titleJournal of Energy Resources Technology, Part A: Sustainable and Renewable Energy
dc.identifier.doi10.1115/1.4070396
dc.treeJournal of Energy Resources Technology, Part A: Sustainable and Renewable Energy:;2026:;volume( 002 ):;issue:001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record