• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Thermal Science and Engineering Applications
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Thermal Science and Engineering Applications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Development of a Modified RANS-Turbulence Model for the Computational Investigation of Film Cooling

    Thumbnail
    View/Open
    tsea-25-1557.pdf (1.881Mb)
    Date
    2026
    Author
    Domnick, Clemens
    Landfester, Christian
    Wiedermann, Alexander
    Böhle, Martin
    Krewinkel, Robert
    Metadata
    Show full item record
    Abstract
    Abstract. The thermal load on the endwalls of the hot gas path of gas turbines, in particular those of the nozzle guide vanes (NGVs), has increased considerably over the last few decades, both because of the common premixed combustion being used and the ever-increasing turbine inlet temperatures. Therefore, cooling concepts for these endwalls have been the focus of R&D efforts for some time. Dedicated cooling, i.e., film-cooling holes in the most thermally highly loaded areas, can be applied. This requires both additional cooling air and costly mechanical efforts. When using purge air, neither of these two disadvantages comes into play. For this reason, cooling the endwalls with purge air from the combustor/NGV interface seems very attractive. To establish and evaluate this cooling concept, dedicated tests are normally performed, but both the required time and financial resources preclude testing every possible geometry. Hence, efforts are made to use CFD to establish the thermal load on the endwalls and the optimum cooling configuration before testing. The thermal load consists of both the film-cooling effectiveness and the heat transfer on the endwall. Combined, these yield the net heat flux ratio (NHFR). Only this gives the true thermal load on the surface. In an industrial environment, Reynolds-averaged Navier–Stokes (RANS) solvers are used to carry out CFD analyses. These have difficulties in modeling shear stresses and turbulence, which means that both the cooling effectiveness and the heat transfer predictions are inaccurate. Therefore, an existing k–ω shear stress transport (SST) model was modified in ansys cfx to better capture these parameters. The model was developed based on film-cooling experiments and validated on extensive experiments of endwall cooling in a linear cascade. In this article, these experiments, the CFD model, and its validation will be presented and discussed in detail.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315360
    Collections
    • Journal of Thermal Science and Engineering Applications

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV