Show simple item record

dc.contributor.authorCicero, Sergio
dc.contributor.authorSánchez, Marcos
dc.date.accessioned2026-08-23T07:32:50Z
dc.date.available2026-08-23T07:32:50Z
dc.date.copyright2026/02/01
dc.date.issued2026
dc.identifier.issn0094-9930
dc.identifier.otherpvt-25-1101.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315254
dc.description.abstractAbstract. The long-term-operation of nuclear power plants (NPPs) requires a precise knowledge of the fracture toughness of the reactor pressure vessel (RPV) materials. This property decreases with the irradiation level, so surveillance programs measure it throughout the NPP operational life by testing materials placed inside the RPV which were initially designed to cover the initial lifespan. Therefore, the amount of available material to be tested during the life extension of NPPs may be scarce, and it is not possible to perform fracture tests using conventional specimens (e.g., 1T or 25.4 mm thick). In this context, mini-C(T) specimens (0.16T) appear as a key technology. Generally, mini-C(T) specimens provide similar results to those generated by using conventional specimens. However, there are situations where the deviations between the T0 predictions of conventional and mini-C(T) specimens are negligible, and situations where such deviations are as high as 40 °C. This work provides a comprehensive literature review of experimental T0 results obtained using conventional fracture specimens and mini-C(T) specimens, analyzing how the corresponding deviations are affected by the number of valid tests used to define T0. The research includes a total of 140 datasets, covering base, heat affected zone (HAZ), and weld materials, and both irradiated and unirradiated conditions. With all this, the paper finally provides insights into how the mentioned deviations depend on the extent of the experimental program performed for the characterization of T0, revealing that larger experimental programs tend to provide smaller discrepancies.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalysis of the Difference Between the Reference Temperature Values Derived From Conventional and Mini-C(T) Specimens: Effect of the Number of Valid Fracture Tests
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4070048
dc.journal.fristpage1085
dc.journal.lastpage1093
dc.page9
dc.treeJournal of Pressure Vessel Technology:;2026:;volume( 148 ):;issue:001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record