dc.description.abstractAbstract. In this work, the electrical contact degradation characteristics of spring blade components in power connectors under a lateral fretting environment are investigated experimentally. The typical evolution processes of contact voltage and temperature at the contact zone as a function of fretting cycles are recorded; together with the surface morphologies and element distribution, a fretting failure map, which could distinguish the failure modes for the combination of load current and normal force, is proposed. The wear-dominated disconnection, wear- and melt erosion co-dominated overheating, melt-erosion-dominated disconnection, and fusion-welding failure modes are summarized. The mechanisms for different erosion patterns at the contact interface are elucidated. The results show that the variations in critical melted radius and cutting force, which depend on current and normal force, are the main reasons for the different degradation modes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental Investigation of Electrical Contact Failure Mechanisms of Spring Blade Components Under Lateral Fretting at Power Current Levels
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue9
dc.journal.titleJournal of Tribology
dc.identifier.doi10.1115/1.4071769
dc.journal.fristpage186
dc.journal.lastpage194
dc.page9
dc.treeJournal of Tribology:;2026:;volume( 148 ):;issue:009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record