Show simple item record

dc.contributor.authorZhang, Yilun
dc.contributor.authorWang, Xin
dc.contributor.authorZhang, Zhinan
dc.date.accessioned2026-08-23T07:25:37Z
dc.date.available2026-08-23T07:25:37Z
dc.date.copyright2026/02/01
dc.date.issued2026
dc.identifier.issn0094-9930
dc.identifier.otherpvt-25-1098.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315077
dc.description.abstractAbstract. The computation of bolts in pipe flange connections has received significant attention in engineering practice. However, few studies have systematically been done to compute member stiffness in the design of tie bolts under nozzle loads. This paper focuses on the critical problem of foot bolt group connections in pressure vessels subjected to nozzle loads, particularly when these loads exceed standard requirements. A method based on the translation of spatial force systems is proposed to determine the equivalent loads on bolt groups. Four primary failure modes including faying translation, faying rotation, angle separation, and parallel separation are analyzed, and corresponding calculation procedures are established. Two distinct methods are proposed to further evaluate the bolt group's strength, and calculation examples and contrast analysis are performed to verify their applicability at different development stages.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Calculation of Foot Bolt Group Connection for Pressure Vessels Under Action of Nozzle Loads
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4070047
dc.treeJournal of Pressure Vessel Technology:;2026:;volume( 148 ):;issue:001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record