dc.description.abstractAbstract. Variable inhalation flow rates reduce aerosol drug efficacy, while separate devices for therapy and monitoring hinder patient adherence. This study computationally designs a novel, dual-function valve to solve these issues. Operating on inertial impaction, the valve uses a nozzle to create an aerosol jet and a movable plate to force a sharp airflow turn. Larger, high-inertia particles impact the plate, while smaller therapeutic particles remain entrained. Building on an optimized geometry, a computational fluid dynamics (CFD) model characterized valve performance across clinically relevant conditions. The model simulated aerosol transport during low-flow therapeutic inhalation (10–60 L/min) and high-flow diagnostic peak expiratory flow rate (PEFR) exhalation (100–700 L/min). A custom “valve efficacy” metric quantified selective particle filtration based on aerodynamic diameter. Filtration efficacy is highly dependent on inhalation flow rate and nozzle-to-plate distance. A high-performance therapeutic window was identified at 20–35 L/min, maintaining efficacy above 90%. A direct, linear relationship between aerodynamic drag on the plate and the optimal filtration distance was established. This enables a passive, self-regulating mechanism governed by a linear spring. Augmenting this with a second, stiffer spring in series allows the assembly to function as a PEFR meter. The computational results validate the feasibility of a single, flow-actuated valve that integrates selective therapeutic aerosol filtration with diagnostic PEFR monitoring. This design represents a significant step toward developing more personalized, effective, and user-friendly devices for managing chronic respiratory diseases.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDesign of a Novel Dual-Function Spacer Valve for Selective Aerosol Size Filtering and Measuring Peak Expiratory Flow Rate
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue8
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4071666
dc.journal.fristpage613
dc.journal.lastpage626
dc.page14
dc.treeJournal of Biomechanical Engineering:;2026:;volume( 148 ):;issue:008