Show simple item record

dc.contributor.authorYogi, Ketan
dc.contributor.authorSahu, Gopinath
dc.contributor.authorQuan, Ian
dc.contributor.authorPatel, Akshat
dc.contributor.authorYang, Yunchun
dc.contributor.authorWei, Tiwei
dc.date.accessioned2026-08-23T07:20:09Z
dc.date.available2026-08-23T07:20:09Z
dc.date.copyright2026/07/01
dc.date.issued2026
dc.identifier.issn2832-8450
dc.identifier.otherht-25-1461.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4314955
dc.description.abstractAbstract. This study experimentally investigates the thermal–hydraulic performance of ultraconfined two-phase jet-impingement cooling using a distributed inlet–outlet nozzle manifold, a configuration that has received limited attention in prior work. It addresses a critical knowledge gap by providing the first experimental characterization of a confined two-phase distributed inlet–outlet jet architecture operating at an ultraconfinement height (z) of 0.33 mm (z/d = 0.66), representative of practical chip-level cooling constraints. Simultaneous measurements of critical heat flux (CHF), pressure drop, and local impingement cavity pressure enable direct evaluation of thermal–hydraulic tradeoffs under strong confinement. Experiments were conducted with the low-global warming potential (GWP) refrigerant R1233zd(E) overflow rates from 0.15 to 1.25 lpm and jet-array densities corresponding to nondimensional jet-to-jet spacing of s/d = 4.0–10.0. The results show that CHF and thermal–hydraulic efficiency are governed by jet-array density in the ultraconfined regime, where liquid momentum, vapor evacuation, and confinement-induced flow resistance are tightly coupled. Maximum CHF values approaching 270 W/cm2 are achieved at ultralow pumping powers below 0.4 W. Direct impingement cavity pressure measurements reveal a transition in the CHF-limiting mechanism from thermally dominated dryout at low flow rates to hydrodynamically constrained operation at higher flow rates. A scaling relationship linking CHF to jet Reynolds number and jet-array spacing is established, providing quantitative design guidance for compact, high-performance ultraconfined two-phase jet-impingement cooling systems.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermal–Hydraulic Performance of Ultra-Confined Two-Phase Jet-Impingement Cooling With Distributed Inlet–Outlet Manifolds
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue7
dc.journal.titleASME Journal of Heat and Mass Transfer
dc.identifier.doi10.1115/1.4071589
dc.journal.fristpage163
dc.journal.lastpage174
dc.page12
dc.treeASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:007
dc.contenttypeFulltext