dc.description.abstractAbstractThe optimal meter placement (OMP) problem for leak detection in water distribution networks (WDNs) has been a serious concern for several decades. Despite the need to minimize detection overlapping for effective OMP, there is a lack of ...
dc.publisherAmerican Society of Civil Engineers
dc.titleMinimization of Leak Detection Overlaps Using Sensitivity Matrix-Based Optimal Meter Placement in Water Distribution Networks
dc.typeJournal Article
dc.journal.volume151
dc.journal.issue12
dc.journal.titleJournal of Water Resources Planning and Management
dc.identifier.doi10.1061/JWRMD5.WRENG-7067
dc.journal.fristpage04025066-1
dc.journal.lastpage04025066-16
dc.page16
dc.treeJournal of Water Resources Planning and Management:;2025:;Volume ( 151 ):;issue: 012