Cleat Angle Behavior in C-Shaped Purlin-to-Rafter Connections: Experimental Study and Design Considerations
View/ Open
Date
2026Author
Hari Narayana, Chandragiri
Naik, Anusha
Naik, Bishal
Madhavan, Mahendrakumar Mathialagu
Metadata
Show full item recordAbstract
AbstractThis research examines the pull-through failure behavior of cold-formed steel (CFS)
C-shaped purlin-to-rafter connections using a cleat angle. A total of 72 tests were
performed to evaluate the influence of cross-sectional parameters, including ...The left section shows C-shaped purlins connected to rafters via cleat angles, supporting
the roof sheeting subjected to wind uplift forces indicated by upward arrows. The
right section presents a test setup simulating wind uplift with a vertical loading
...Practical ApplicationsUsing a cleat angle to connect the purlin to the rafter provides significant advantages
over direct screw connections of the purlin to the rafter. The advantages include
lesser impact of the connection failure at high speed winds ...