dc.description.abstractAbstractDirect current (DC) traction systems such as a subway can cause time-resolved stray current interference in adjacent gas pipelines, leading to serious corrosion risk. It is important to evaluate risk according to the field test. In this paper, a ...Practical ApplicationsThis study proposes a corrosion risk assessment method that provides intuitive and reliable decision support for underground pipeline maintenance. Taking a natural gas pipeline along a metro line as an example, long-term monitoring ...
dc.publisherAmerican Society of Civil Engineers
dc.titleCorrosion Risk Assessment of Steel Gas Pipelines under Dynamic DC Interference according to In Situ Measurements
dc.typeJournal Article
dc.journal.volume17
dc.journal.issue2
dc.journal.titleJournal of Pipeline Systems Engineering and Practice
dc.identifier.doi10.1061/JPSEA2.PSENG-1908
dc.journal.fristpage04026008-1
dc.journal.lastpage04026008-10
dc.page10
dc.treeJournal of Pipeline Systems Engineering and Practice:;2026:;Volume ( 017 ):;issue: 002